🔍 Load Bank & Resistor Cooling Fan

Load Bank
Cooling Fan

Forced-air cooling fans for generator set and UPS load test bank resistor cooling. Matched to resistor power rating, controller-interlocked. IS 3588. Mumbai manufacturer.

Load Bank Cooling Fan
20+Years Experience
500+Projects Delivered
50+Fan Variants
25+Export Countries
IS 3588Compliant
Product Overview

Load Bank Cooling Fan — Manufacturer & Supplier, India

Vayuvents manufactures Load Bank Cooling Fans for forced-air cooling of generator set and UPS load test banks. IS 3588 compliant. Mumbai. Call +91 90961 88703.

A Load Bank Cooling Fan provides the forced-air cooling essential for safe and sustained generator set load testing. During a generator load test, the resistor load bank dissipates the generator's full rated electrical output as heat — heat that must be removed continuously to keep the resistors within their temperature rating.

Vayuvents designs and supplies load bank cooling fans for generator test facilities, mobile load bank trailers, containerised load banks, and fixed installation test bays. Fan capacity is calculated based on the load bank kW rating, resistor matrix dimensions, and allowable resistor operating temperature.

For mobile load banks on trailers and containers, compact direct-drive axial fans are standard — providing maximum airflow in minimum space. For fixed test bays with large load banks (500 kW to 5 MW), multiple large-diameter axial fans or centrifugal blowers provide the required volume.

All load bank cooling fans are controller-interlocked — the fan cannot be stopped while the load bank is energised, and the load bank cannot be energised without the fan running.

Key Features

Key Features & Benefits

Matched to Resistor Power

Fan airflow matched to load bank resistor kW rating — adequate cooling at 100% rated load without over- or under-ventilating the resistor matrix.

🌡️

High Thermal Load

Sized to remove full thermal output of resistors — typically 80 to 120 m³/hr cooling air per kW of resistor heat dissipation.

🔒

IP55 Motor

IP55 TEFC motor for dusty generator test areas, outdoor containerised load banks, and high-temperature generator rooms.

🔌

Controller Interlocked

Fan start/stop interlocked with load bank controller — fan always running when resistors are energised, preventing unattended operation without cooling.

📐

Custom Integration

Fan sized to specific load bank enclosure dimensions — flanged connection to resistor bay with correct airflow path through resistor matrix.

💨

High Static Pressure

Centrifugal or high-pressure axial for compact multi-row resistor stacks with high internal resistance.

🏗️

Robust Construction

Heavy-gauge MS casing for vibration, diesel fumes, and high ambient temperatures of generator test areas.

IS 3588 / IS 4894 Compliant

Fan performance tested per IS 3588-1987 with test certificate confirming stated airflow and pressure.

Technical Specifications

Technical Specifications

ParameterSpecification
Airflow Capacity5,000 to 1,00,000 m³/hr
Static Pressure20 to 150 mmWG
Motor Power0.75 HP to 30 HP
Fan TypeAxial / Centrifugal
Motor EnclosureIP55 TEFC
ConstructionMS / SS304
Power Supply415V 3-Phase 50Hz
ControlController interlocked start/stop
StandardsIS 3588-1987 | IS 4894
Product Gallery

Product Images

Load Bank Cooling Fan Resister Bank Cooling Fan Generator Load Bank Fan Cooling Fan Range
Applications

Where It Is Used

  • Generator set rated load testing at 25%, 50%, 75%, and 100% load
  • UPS and inverter load testing and commissioning acceptance tests
  • Transformer load testing before energisation
  • Dynamic braking resistors for overhead cranes and hoists
  • Elevator and escalator dynamic braking resistor cooling
  • VFD harmonic filter resistor cooling
  • Neutral earthing resistor cooling in MV switchgear
  • Power electronics converter and rectifier heat sink cooling
  • Battery charger and rectifier bank cooling
  • Naval and offshore generator load testing facilities
  • Renewable energy inverter test facility load banks
  • Containerised mobile load banks for site generator testing
Related Products

You May Also Need

Resister Bank Cooling Fan

Resister Bank Cooling Fan

Cooling fans for resistor bank assemblies in braking and power electronics.

View Details →
Resistor Load Bank Cooling Fan

Resistor Load Bank Cooling Fan

Load bank cooling fans for generator test facilities.

View Details →
Axial Flow Fan

Axial Flow Fan

Industrial axial fans for general equipment cooling.

View Details →
Belt Driven Axial Fan

Belt Driven Axial Fan

Belt driven fans for high-temperature generator room service.

View Details →
Frequently Asked Questions

FAQs — Load Bank Cooling Fan

A load bank creates artificial electrical load for testing generator sets and UPS systems. The resistor elements dissipate the test load entirely as heat — which must be force-cooled continuously during testing. Without adequate forced-air cooling, resistors overheat and burn out within seconds at rated load.

80 to 120 m³/hr of cooling air per kW of resistor load is the standard rule. For a 500 kW load bank: 40,000 to 60,000 m³/hr required. The fan must also overcome internal resistor matrix resistance — typically 30 to 80 mmWG. Vayuvents calculates the correct size from your load bank kW rating and enclosure layout.

For large-area resistor banks with low matrix resistance: high-volume axial fans. For compact multi-row stacks with high internal resistance: centrifugal blowers or high-pressure axial fans. Vayuvents recommends the correct type based on the resistor enclosure dimensions and matrix configuration.

Resistors begin to overheat immediately. Most load banks have thermal protection that disconnects the resistor load within seconds of cooling fan failure. The generator test halts until the fan is repaired. Vayuvents recommends keeping a spare fan motor on-site for immediate replacement.

Yes. For mobile load bank trailers and containers, compact direct-drive axial fans providing maximum airflow in minimum space are standard. Vayuvents supplies fans matched to the trailer or container enclosure with flanged connections for clean integration.

Yes. In most load bank configurations, the cooling fan forces air through the resistor matrix and the heated air exhausts through the opposite end of the enclosure — the fan simultaneously cools the resistors and exhausts the heated air. No separate exhaust fan is required.

Contact Vayuvents at enquiry@vayuvents.com or call +91 90961 88703. Share the load bank resistor power rating in kW, enclosure internal dimensions, and existing fan opening size. We will calculate the required airflow and provide a commercial proposal within 24 hours.

Load Bank Cooling Fan — Quote Within 24 Hours

Share load bank kW rating, enclosure dimensions, and fan opening size — we will calculate correct airflow and provide a commercial proposal same day.