Transformer Cooling Fan for Data Centre — Manufacturer & Supplier
Vayuvents Pvt. Ltd. manufactures and supplies transformer cooling fans for data centre applications across India and export markets.
Data centres are among the most power-critical facilities in modern infrastructure — requiring transformer cooling fans with exceptional reliability, low acoustic noise, and ability to operate continuously without maintenance intervention in the air-conditioned environment of a data centre electrical room.
Data centre transformers include the main HV/MV intake transformer, multiple UPS bypass transformers, and generator step-up/step-down transformers — all of which require ONAF cooling fans matched to their specific cooling class rating.
Vayuvents supplies transformer cooling fans for India's fast-growing data centre sector — with hyperscale and enterprise data centres in Mumbai, Chennai, Pune, Hyderabad, NCR, and Bengaluru all requiring highly reliable power infrastructure including transformer cooling systems.
How It Works in This Application
Transformer Heat Generation
Data centre transformers operate at high, consistent load factors (70 to 90 percent of rated capacity) — generating continuous heat that requires sustained ONAF cooling.
ONAF Cooling Activation
ONAF fans activate via OTI/WTI thermostat when transformer temperature reaches the setpoint — typically at 90 percent load or during high-ambient conditions in the transformer room.
Low-Noise Operation Requirement
Data centre electrical rooms are often located within or adjacent to occupied spaces — requiring low-noise fan operation to meet building acoustic standards.
High-Availability Operation
Data centre power infrastructure requires 99.99 percent uptime — transformer cooling fans must be highly reliable and fan failure alarm must trigger immediate response.
Recommended Variants
Low-Noise Radiator Fan
Optimised blade design for low acoustic output — critical for data centre electrical room noise compliance.
Most RecommendedRedundant Fan Array
N+1 or 2N fan configuration where failure of any single fan does not reduce cooling capacity below required level.
Temperature-Controlled Fan
Fan with integrated PT100 or thermocouple temperature sensor and controller for precision temperature-based speed control.
Enhanced IP Rating Fan
IP65 rated fan for transformer rooms with higher humidity or water spray risk.
Technical Specifications
| Parameter | Specification |
|---|---|
| Airflow Capacity | 500 to 20,000 m3/hr per fan |
| Motor Power | 0.04 kW to 2.2 kW |
| Fan Diameter | 200 to 800 mm |
| Voltage | 415V / 230V 3-phase and single-phase |
| Motor Enclosure | TEFC IP55 as standard |
| Blade Material | Aluminium / PP |
| Standards | IS 4894, IEC 60076 |
Key Features
- Compact direct-drive design with motor integrated in fan hub — fits standard transformer radiator mounting brackets
- IP55 TEFC motor as standard for outdoor substation and industrial installation in all weather conditions
- Low-noise operation essential for transformer substations in residential and commercial areas
- Aluminium and PP blades are lightweight and non-sparking for safe electrical equipment mounting
- Thermal protector built into motor winding protects against overheating if airflow is obstructed
- Available in 415V 3-phase and 230V single-phase for compatibility with transformer auxiliary supplies
- Long-life factory-sealed bearings require no periodic lubrication for maintenance-free operation
- Works performance test certificate with measured airflow and motor power data
Industries That Use This Application
Hyperscale Data Centres
Transformer cooling fans for 50+ MW hyperscale data centres operated by AWS, Google, Microsoft, and Meta in India
Enterprise Data Centres
Cooling fans for enterprise data centre UPS and substation transformers in corporate and government facilities
Colocation Facilities
Transformer cooling fans for co-location data centre power infrastructure operated by STT, Nxtra, Yotta, and others
Financial Institution Data Centres
High-reliability transformer fans for banks, stock exchanges, and insurance company mission-critical data centres
Hospital Data Centres
Transformer cooling fans for hospital management information systems and medical imaging data centres
Industrial IoT Infrastructure
Edge data centre and factory automation server room transformer cooling fans in smart manufacturing facilities
Telecom Data Centres
Transformer cooling fans for telecom exchange buildings, BSNL, Jio, and Airtel data centre transformers
Transportation Data Centres
Railway, metro, and airport data centre transformer cooling fans for critical transport infrastructure
✓ Supply & Support: Vayuvents manufactures data centre transformer cooling fans at our Vasai, Mumbai works. We supply to data centre EPC contractors, MEP consultants, and facility managers across India. We provide low-noise and high-reliability specifications for mission-critical applications.
FAQs
Data centre electrical rooms typically require transformer cooling fan noise levels below 65 dB(A) at 1 metre to comply with building acoustic standards and ensure acceptable noise levels in adjacent occupied spaces. Vayuvents provides measured noise data for all transformer cooling fan models and can specify low-noise variants for data centre applications.
Data centres implement N+1 or 2N fan redundancy where failure of any single fan does not reduce cooling capacity. Fan failure alarms are wired to the DCIM (Data Centre Infrastructure Management) system for immediate notification. Vayuvents recommends keeping spare fans on-site at all times for immediate replacement, and provides fan selection that allows N+1 fan arrangements on the transformer radiator bank.
Data centres monitor transformer cooling fan status (running/stopped/failed) as part of the DCIM system. Each fan motor should have a current monitoring relay that detects motor failure. Vayuvents can supply fans with motor current monitoring relay contacts wired for connection to the DCIM or BMS system for real-time fan status monitoring.
Yes. Variable frequency drive (VFD) control of transformer cooling fans allows speed reduction during partial-load periods (typically nights and weekends in commercial data centres), significantly reducing fan power consumption. VFD-controlled cooling also reduces motor thermal stress and extends fan life. Vayuvents supplies VFD-compatible motor windings for all transformer cooling fan sizes.
Vayuvents transformer cooling fans with factory-sealed bearings and IP55 motor enclosures are designed for 80,000 to 100,000 hours of continuous operation (approximately 10 to 12 years) in normal data centre electrical room conditions. This is achieved through premium-grade bearing selection, tight motor manufacturing tolerances, and consistent quality control in our Vasai manufacturing facility.
Yes. Vayuvents supplies transformer cooling fans for all data centre tiers including Tier III (N+1 concurrently maintainable) and Tier IV (fault tolerant) facilities. We provide the documentation required for MEP design review including fan noise data, power consumption, and airflow performance curves.
Contact Vayuvents at enquiry@vayuvents.com or call +91 90961 88703. Share the transformer MVA rating, fan dimensions, required noise limit, supply voltage, and quantity. We will provide a specification-matched selection and commercial proposal within 24 hours.