Electric Roof Ventilator Fan — Manufacturer & Supplier, India
Vayuvents manufactures Electric Roof Ventilator Fans — motor-driven rooftop exhaust fans for factories, warehouses, and industrial buildings. 300 mm to 1,800 mm, IS 3588. Mumbai. Call +91 90961 88703.
An Electric Roof Ventilator Fan is a motor-driven roof exhaust unit that provides consistent, controlled rooftop exhaust ventilation powered by electricity — as opposed to wind-driven turbo ventilators that rely on outdoor wind availability. The electric motor ensures full specified exhaust airflow in all weather conditions, including the completely calm days common during Indian monsoon and summer seasons.
Vayuvents electric roof ventilator fans are used wherever reliable, measurable building ventilation is required — factories needing defined air change rates per hour for thermal comfort, buildings with process fumes requiring continuous dilution, and facilities where ventilation inadequacy directly impacts production quality or worker health and safety.
Available from 300 mm to 1,800 mm throat diameter in GI, MS, FRP, SS304, and aluminium cowl construction. VFD (variable frequency drive) compatible motors available for speed-controlled operation — reducing fan speed and power during cooler periods to save energy while maintaining ventilation continuity.
IS 3588 performance tested. Export supply to UAE, Saudi Arabia, Qatar, and Oman with full documentation. Custom sizes and high-temperature motor variants available.
Key Features & Benefits
Rooftop Heat Extraction
Extracts hot accumulated air from the roof level directly — removing the heat stratification layer that makes factory floors uncomfortable and reduces worker productivity.
Weatherproof Cowl
Integrated aerodynamic weather cowl with rain deflector prevents rain, bird entry, and wind-driven debris from entering the building through the roof opening.
Motorised Operation
Electric motor-driven impeller provides consistent, controlled exhaust airflow regardless of wind speed or direction — unlike wind-driven turbo ventilators that stop in calm weather.
IP55 Motor
IP55 TEFC motor withstands the rooftop environment — direct sunlight, rain, dust, and temperature extremes without motor winding failure.
Wide Size Range
300 mm to 1,800 mm throat diameter covers 2,500 m³/hr to 75,000 m³/hr per unit — single or multiple units to match any building exhaust requirement.
Material Options
GI, MS, SS304, aluminium, and FRP cowl and casing options for corrosive chemical plant, coastal, food processing, and pharmaceutical rooftop environments.
Low Noise
Carefully selected impeller speed and aerodynamic blade profiles minimise noise — suitable for factories in residential proximity and noise-sensitive manufacturing environments.
IS 3588 Compliant
Airflow and pressure performance tested per IS 3588-1987 with test certificate confirming stated exhaust performance.
Technical Specifications
| Parameter | Specification |
|---|---|
| Throat Diameter Range | 300 mm to 1,800 mm |
| Airflow (Free Air) | 2,500 m³/hr to 75,000 m³/hr per unit |
| Motor Power Range | 0.25 HP to 10 HP |
| Motor Speed | 960 / 1,440 RPM |
| Motor Enclosure | IP55 TEFC (standard) |
| Motor Insulation | Class F |
| Casing / Cowl Material | GI sheet / MS / SS304 / Aluminium / FRP |
| Blade Material | Aluminium alloy / FRP |
| Power Supply | 415V 3-Phase 50Hz |
| Rain Protection | Weather cowl with rain deflector as standard |
| Standards | IS 3588-1987 | IS 4894 |
Airflow Performance — Model Range
| Sr No. | Model | Fan Dia (mm) | Motor (HP/Pole) | RPM | Free Air (m³/hr) | @15 mmWG | @20 mmWG | @25 mmWG |
|---|---|---|---|---|---|---|---|---|
| 1 | MRF-100-96-24 | 610 | 1.0/4P | 1440 | 11,200 | 11,000 | — | — |
| 2 | MRF-150-96-32 | 810 | 1.5/6P | 960 | 17,288 | — | 16,800 | — |
| 3 | MRF-300-96-36 | 910 | 3.0/6P | 960 | 28,110 | — | — | 28,000 |
| Sr No. | Model | Plate Size (A) | B (mm) | D (mm) | C Min (mm) | C Max (mm) | Weight (kg) | Max Motor Frame |
|---|---|---|---|---|---|---|---|---|
| 1 | MRF-100-96-24 | 1800×1065×4mm | 615 | 200 | 400 | 450 | 45 | 80 |
| 2 | MRF-150-96-32 | 2000×1065×5mm | 815 | 200 | 500 | 550 | 60 | 90L |
| 3 | MRF-300-96-36 | 2000×1200×7mm | 915 | 250 | 600 | 650 | 85 | 112M |
- Fan selection based on air at 20°C, density 1.2 kg/m³.
- Fan performance and tolerance as per IS 3588-1987.
Product Images
Where It Is Used
- Factory and manufacturing plant rooftop heat exhaust — removing hot stratified air from roof level
- Warehouse and logistics hub general ventilation — continuous fresh air turnover
- Foundry and forge shop — high-temperature heat and fume exhaust from roof
- Chemical plant production buildings — corrosive vapour dilution exhaust
- Food processing plants — steam, heat, and odour exhaust from bakery, dairy, and cannery rooftops
- Pharmaceutical manufacturing buildings — GMP-compliant rooftop exhaust ventilation
- Textile mills — lint, humidity, and heat exhaust from spinning and weaving halls
- Automotive paint shops — solvent vapour and heat exhaust from body shop rooftops
- Welding and fabrication shops — welding fume general dilution roof exhaust
- Cold storage and logistics facilities — heat and moisture exhaust from dock areas
- Agricultural processing — grain, spice, and food processing building heat exhaust
- Marine and shipyard fabrication sheds — heat and welding fume rooftop exhaust
You May Also Need
Frequently Asked QuestionsFAQs — Electric Roof Ventilator Fan
A motorised roof ventilator is powered by an electric motor — it exhausts a fixed, controlled volume of air regardless of outdoor wind speed or direction. A wind-driven turbo ventilator (turbine ventilator) relies entirely on wind energy and provides no airflow in calm weather. For reliable, consistent exhaust ventilation in factories and industrial buildings, motorised roof ventilators are always recommended over wind-driven units.
For a 10,000 sq m factory with 8 metre ceiling height requiring 6 air changes per hour, the total exhaust airflow needed is approximately 480,000 m³/hr. This requires 8 to 12 units of RV-100-96-1800 (75,000 m³/hr each) or 12 to 16 units of RV-750-14-1500 (55,000 m³/hr each), arranged uniformly across the roof to avoid stagnant pockets. Vayuvents provides free layout and sizing calculations based on your building dimensions and required air change rate.
For standard factory and warehouse use, GI (galvanised iron) sheet cowl is supplied. For chemical plant rooftops with corrosive acid fumes, coastal environments, and food processing plants, FRP (fibre-reinforced plastic) or SS304 cowl and casing are available. The blade material is also matched — aluminium for standard duty, FRP for corrosive service. Please specify the corrosive agent when requesting a quotation.
Standard motorised roof ventilators are rated for normal temperature exhaust service only and should not be used as fire smoke exhaust fans unless specifically designed and certified for that purpose. Fire smoke exhaust fans require high-temperature motor ratings (typically 300°C for 2 hours), smoke-rated bearings, and fire damper integration per NBC 2016 requirements. Vayuvents can supply dedicated smoke exhaust fan variants — please specify if fire smoke extraction is required.
Roof ventilators should be spaced at maximum 10 to 15 times the ceiling height — for an 8 metre ceiling, maximum 80 to 120 metre spacing. They should be distributed uniformly across the roof to avoid stagnant areas and positioned at the ridge or highest roof point where hot air naturally accumulates. Corresponding fresh air supply openings (louvres or supply fans) should be provided at low level on the opposite side of the building.
Yes. For foundry and forge buildings with high heat loads, Vayuvents supplies heavy-duty roof ventilators with Class H motor insulation (180°C winding rating) for the high ambient temperature at roof level in these buildings. The cowl is in MS with heat-resistant paint for the elevated roof ambient. Anti-corrosion and spark-resistant blade options are available for foundry environments.
Contact Vayuvents at enquiry@vayuvents.com or call +91 90961 88703. Share the building dimensions (length × width × height), required air changes per hour, roof type (sheeted, RCC, sawtooth), and any special requirements (corrosion, high temperature, food grade). We will calculate the required number and size of units and provide a layout drawing and commercial proposal within 24 hours.