📍 Manufacturers & Exporters — Vasai, Mumbai, India 📞 +91 90961 88703  |  ✉ enquiry@vayuvents.com
Vayuvents Pvt. Ltd.
VAYUVENTSPvt. Ltd. — Industrial Fans & Blowers
📞 Call Now 💬 WhatsApp
🔍 Axial Flow Fan — Wall Mounted Tube Axial Variant

Wall Mounted Industrial
Tube Axial Fan

Through-wall tube axial fans for exhaust ventilation and fresh air supply in factories, warehouses, server rooms, and process buildings. Compact circular casing fits standard wall openings. IS 3588 compliant manufacturer & exporter from Mumbai, India.

Wall Mounted Industrial Tube Axial Fan
20+Years Experience
500+Projects Delivered
50+Fan Variants
25+Export Countries
IS 3588Compliant
Product Overview

Wall Mounted Industrial Tube Axial Fan — Manufacturer & Supplier, India

Vayuvents manufactures Wall Mounted Industrial Tube Axial Fans for through-wall exhaust and fresh air supply in factories, warehouses, workshops, and process buildings. 305 mm to 1,220 mm dia, IS 3588 compliant. Mumbai manufacturer. Call +91 90961 88703.

A Wall Mounted Industrial Tube Axial Fan is a direct-drive axial fan in a tubular circular casing specifically designed for through-wall installation — inserted into a circular opening in the building wall to provide forced exhaust ventilation or fresh air supply without requiring floor space or overhead structure.

The tube axial configuration places the motor and impeller coaxially inside a short tubular casing, making the unit compact and self-contained. The casing flanges are bolted directly to the wall on both faces, and the unit requires only an electrical supply connection. Louvres or weather-protective grilles are fitted on the external face to prevent rain ingress and bird entry when the fan is stopped.

Vayuvents manufactures wall mounted tube axial fans in the 305 mm to 1,220 mm diameter range, covering airflow from 1,800 m³/hr to 69,000 m³/hr. Larger sizes (1,530 mm and above) are more commonly supplied in base-mounted or stand-mounted configuration due to the structural wall load requirements at those sizes.

Available with reversible motors for two-direction airflow (supply in winter, exhaust in summer), with automatic back-draught shutters, and with corrosion-resistant FRP or SS casings for chemical plant and coastal environments.

Key Features

Key Features & Benefits

🧱

Through-Wall Installation

Self-contained tubular casing fits into a standard circular wall opening — no floor space required, suitable for solid walls, sandwich panels, and sheet metal wall cladding.

💨

Bidirectional Option

Reversible motor option allows the same fan to supply fresh air or exhaust stale air — useful for seasonal ventilation reversal in warehouses and cold-storage buildings.

🔒

Back-Draught Shutter

Automatic gravity-operated back-draught shutters on the external face prevent reverse airflow, rain ingress, and bird entry when the fan is stopped.

🌀

Compact Tube Casing

Short tubular casing minimises wall penetration depth — suitable for thin structural walls, hollow-block walls, and insulated sandwich panel construction.

🔧

Flange Mount

Circular flanged casing bolts directly to the wall opening on both faces — secure, weatherproof installation without additional framing or support structure.

🌿

Low Energy Consumption

Efficient aerodynamic impeller and appropriately selected motor speed deliver required airflow with minimum power consumption — lower running cost than oversized fans.

🌊

Weatherproof Variants

FRP or SS316 casing options for coastal, chemical, and corrosive atmosphere wall installations where MS painted casing would corrode.

IS 3588 Certified

Airflow and pressure tested per IS 3588-1987 with test certificate — confirms stated performance is delivered at the installed operating point.

Technical Specifications

Technical Specifications

ParameterSpecification
Fan Diameter Range305 mm (12") to 1,220 mm (48")
Airflow (Free Air)1,800 m³/hr to 69,000 m³/hr
Motor Power Range0.25 HP to 10 HP
Motor Speed960 / 1,440 / 2,800 RPM
Motor EnclosureIP55 TEFC (standard)
Casing MaterialMS / FRP / SS304 (as specified)
MountingThrough-wall circular flanged casing
External Face ProtectionBack-draught shutters / Weather grille / Bird guard
Power Supply415V 3-Phase 50Hz | 230V Single-Phase (small sizes)
StandardsIS 3588-1987 | IS 4894
Performance Data

Airflow Performance — Model Range

Sr.ModelDia (mm)Motor (HP/Pole)RPMFree Air (m³/hr)@10 mmWG@15 mmWG@20 mmWG@25 mmWG@30 mmWG
1AX-75-28-1203050.75/2P28002,3002,0001,7501,400
2AX-25-14-1203050.25/4P14401,8001,5001,4501,320
3AX-50-14-1503850.50/4P14402,2501,200
4AX-75-28-1503850.75/2P28505,0004,1003,9003,7003,3003,000
5AX-50-14-1804600.50/4P14406,7505,5004,400
6AX-100-28-1804601.0/2P28809,0007,5006,200
7AX-100-14-2406121.0/4P144012,00011,00010,9009,500
8AX-200-28-2406122.0/2P280015,50013,60013,00011,300
9AX-150-14-2807121.5/4P144017,50015,00013,90012,50011,80010,000
10AX-300-28-2807123.0/2P288020,00018,50016,90016,00015,00014,500
11AX-300-96-3609153.0/6P96045,00042,00039,00037,00034,000
12AX-500-14-3609155.0/4P144040,00038,00035,00032,000
13AX-500-96-40010155.0/6P96048,00045,00043,00042,000
14AX-750-14-40010157.5/4P144055,00049,00047,000
15AX-750-96-48012207.5/6P96065,00058,00055,00034,50030,500
16AX-100-960-480122010/6P96069,00065,00061,50060,000
17AX-150-960-600153015/6P96075,00080,000
18AX-300-14-600153030/4P144095,000
19AX-300-96-720183030/6P9601,20,000
20AX-500-14-720183050/4P14401,50,000
  • Fan selection based on air at 20°C, density 1.2 kg/m³.
  • Performance and tolerance as per IS 3588-1987.
  • Custom sizes and intermediate performance points available on request.
Product Gallery

Product Images

Wall Mounted Industrial Tube Axial FanFactory Wall Mounted Axial FanTube Axial Fan RangeAxial Fan Installation
Applications

Where It Is Used

  • Factory side-wall exhaust ventilation — removing heat, fumes, and stale air
  • Warehouse fresh air supply — through-wall supply fans on windward wall
  • Server rooms and UPS rooms — continuous heat exhaust through external wall
  • Transformer and electrical switch rooms — forced cooling air supply
  • Kitchen and canteen exhaust — smoke and cooking fumes through external wall
  • Chemical plant storage buildings — solvent vapour dilution and purge ventilation
  • Battery charging rooms — hydrogen dilution exhaust through external wall
  • Toilet blocks and locker room exhaust ventilation
  • Cold storage buildings — defrost air circulation and heat removal
  • Car workshop and service bays — exhaust fume extraction through external wall
  • Pharmaceutical tablet coating room exhaust — solvent removal
  • Laboratory exhaust ventilation — chemical fume dilution
Related Products

You May Also Need

Stand Mounted Fresh Air Fan

Stand Mounted Fresh Air Fan

Flexible floor-standing fresh air supply — repositionable without wall penetration.

View Details →
Base Mounted Axial Fan

Base Mounted Axial Fan

Permanent floor installation for high-capacity fresh air supply and exhaust.

View Details →
Flameproof Floor Mounted Fan

Flameproof Floor Mounted Fan

IS 5572 flameproof for Zone 1 & 2 hazardous area exhaust ventilation.

View Details →
Belt Driven Axial Fan

Belt Driven Axial Fan

Belt-drive variant for high-temperature and corrosive wall exhaust applications.

View Details →
Frequently Asked Questions

FAQs — Wall Mounted Industrial Tube Axial Fan

The wall opening diameter should be 10 to 20 mm larger than the fan casing outer diameter to allow for installation and sealing. For example, a 610 mm (24") tube axial fan casing typically requires a 630 to 640 mm diameter wall opening. Vayuvents provides the exact required opening dimensions with each fan supply.

Yes. Reversible single-phase and three-phase motors are available for tube axial fans requiring both supply and exhaust operation from the same fan position. The motor rotates in reverse to change airflow direction. However, note that reversed airflow efficiency is slightly lower than forward airflow in standard blade profiles. Vayuvents offers symmetrical blade profile impellers for equal supply and exhaust performance on request.

For outdoor-facing installations, Vayuvents recommends: (1) automatic back-draught shutters that close when the fan is stopped — prevents rain ingress and reverse airflow from wind; (2) aluminium or GRP louvred bird guard to prevent bird nesting; and (3) GI or SS weatherhood for installations in areas with heavy rain or monsoon exposure. All external accessories are supplied and fitted at Vayuvents works.

Standard MS casing fans are not suitable for corrosive chemical fumes. For chemical plant storage buildings, acid fume exhaust, and coastal environments, Vayuvents supplies tube axial fans with FRP (fibre-reinforced plastic) or SS304/316 casings and GRP anti-static impellers that resist chemical attack. Please specify the chemical or corrosive medium when requesting a quotation.

Standard Vayuvents tube axial fan casings accommodate wall thicknesses up to 300 mm. For thicker walls (300 mm to 600 mm), an extended casing length is available on request. For walls above 600 mm thickness, a flanged duct connection to the fan is recommended rather than a longer casing.

Yes. Vayuvents supplies GMP-compatible wall mounted tube axial fans in SS304 or SS316L casing for pharmaceutical production buildings, food processing plants, and clean room exhaust applications. These are supplied with smooth internal surfaces, no dead zones, and are designed for wet cleaning with water and disinfectant.

Contact Vayuvents at enquiry@vayuvents.com or call +91 90961 88703. Share the wall thickness, required airflow in m³/hr, wall opening size if already cut, and any special requirements (reversible, chemical-resistant, flameproof). We will provide a selection and commercial proposal within 24 hours.

Wall Mounted Tube Axial Fan — Quote Within 24 Hours

Share your wall thickness, airflow requirement, and casing material preference — we will provide a matched selection and commercial proposal same day.

✉ Send Enquiry📞 +91 90961 88703