Wall Mounted Industrial Tube Axial Fan

Through-wall tube axial fans for exhaust ventilation and fresh air supply in factories, warehouses, server rooms, and process buildings. Compact circular casing fits standard wall openings. IS 3588 compliant manufacturer & exporter from Mumbai, India.

Wall Mounted Industrial Tube Axial Fan — Manufacturer & Supplier, India

Vayuvents manufactures Wall Mounted Industrial Tube Axial Fans for through-wall exhaust and fresh air supply in factories, warehouses, workshops, and process buildings. 305 mm to 1,220 mm dia, IS 3588 compliant. Mumbai manufacturer.

A Wall Mounted Industrial Tube Axial Fan is a direct-drive axial fan in a tubular circular casing specifically designed for through-wall installation — inserted into a circular opening in the building wall to provide forced exhaust ventilation or fresh air supply without requiring floor space or overhead structure.

The tube axial configuration places the motor and impeller coaxially inside a short tubular casing, making the unit compact and self-contained. The casing flanges are bolted directly to the wall on both faces, and the unit requires only an electrical supply connection. Louvres or weather-protective grilles are fitted on the external face to prevent rain ingress and bird entry when the fan is stopped.

Vayuvents manufactures wall mounted tube axial fans in the 305 mm to 1,220 mm diameter range, covering airflow from 1,800 m³/hr to 69,000 m³/hr. Larger sizes (1,530 mm and above) are more commonly supplied in base-mounted or stand-mounted configuration due to the structural wall load requirements at those sizes.

Available with reversible motors for two-direction airflow (supply in winter, exhaust in summer), with automatic back-draught shutters, and with corrosion-resistant FRP or SS casings for chemical plant and coastal environments.

Key Features & Benefits

🧲

Through-Wall Installation

Self-contained tubular casing fits into a standard circular wall opening — no floor space required, suitable for solid walls, sandwich panels, and sheet metal wall cladding.

💨

Bidirectional Option

Reversible motor option allows the same fan to supply fresh air or exhaust stale air — useful for seasonal ventilation reversal in warehouses and cold-storage buildings.

🔒

Back-Draught Shutter

Automatic gravity-operated back-draught shutters on the external face prevent reverse airflow, rain ingress, and bird entry when the fan is stopped.

🌐

Compact Tube Casing

Short tubular casing minimises wall penetration depth — suitable for thin structural walls, hollow-block walls, and insulated sandwich panel construction.

🔧

Flange Mount

Circular flanged casing bolts directly to the wall opening on both faces — secure, weatherproof installation without additional framing or support structure.

🌿

Low Energy Consumption

Efficient aerodynamic impeller and appropriately selected motor speed deliver required airflow with minimum power consumption — lower running cost than oversized fans.

🌊

Weatherproof Variants

FRP or SS316 casing options for coastal, chemical, and corrosive atmosphere wall installations where MS painted casing would corrode.

✅

IS 3588 Certified

Airflow and pressure tested per IS 3588-1987 with test certificate — confirms stated performance is delivered at the installed operating point.

Technical Specifications

Parameter Specification
Fan Diameter Range 305 mm (12") to 1,220 mm (48")
Airflow (Free Air) 1,800 m³/hr to 69,000 m³/hr
Motor Power Range 0.25 HP to 10 HP
Motor Speed 960 / 1,440 / 2,800 RPM
Motor Enclosure IP55 TEFC (standard)
Casing Material MS / FRP / SS304 (as specified)
Mounting Through-wall circular flanged casing
External Face Protection Back-draught shutters / Weather grille / Bird guard
Power Supply 415V 3-Phase 50Hz | 230V Single-Phase (small sizes)
Standards IS 3588-1987 | IS 4894

Airflow Performance — Model Range

Free air delivery (m³/hr) at increasing static pressure (mm WG), across the full model range.

Sr Model Dia (mm) Motor (HP/Pole) RPM Free Air (m³/hr) @10 mmWG @15 mmWG @20 mmWG @25 mmWG @30 mmWG
1 AX-75-28-120 305 0.75/2P 2800 2,300 2,000 1,750 1,400 - -
2 AX-25-14-120 305 0.25/4P 1440 1,800 1,500 1,450 1,320 - -
3 AX-50-14-150 385 0.50/4P 1440 2,250 1,200 - - - -
4 AX-75-28-150 385 0.75/2P 2850 5,000 4,100 3,900 3,700 3,300 3,000
5 AX-50-14-180 460 0.50/4P 1440 6,750 5,500 4,400 - - -
6 AX-100-28-180 460 1.0/2P 2880 9,000 7,500 6,200 - - -
7 AX-100-14-240 612 1.0/4P 1440 12,000 11,000 10,900 9,500 - -
8 AX-200-28-240 612 2.0/2P 2800 15,500 13,600 13,000 11,300 - -
9 AX-150-14-280 712 1.5/4P 1440 17,500 15,000 13,900 12,500 11,800 10,000
10 AX-300-28-280 712 3.0/2P 2880 20,000 18,500 16,900 16,000 15,000 14,500
11 AX-300-96-360 915 3.0/6P 960 45,000 42,000 39,000 37,000 34,000 -
12 AX-500-14-360 915 5.0/4P 1440 40,000 - - 38,000 35,000 32,000
13 AX-500-96-400 1015 5.0/6P 960 48,000 45,000 43,000 42,000 - -
14 AX-750-14-400 1015 7.5/4P 1440 55,000 49,000 47,000 - - -
15 AX-750-96-480 1220 7.5/6P 960 65,000 - 58,000 55,000 34,500 30,500
16 AX-100-960-480 1220 10/6P 960 69,000 - - 65,000 61,500 60,000
17 AX-150-960-600 1530 15/6P 960 75,000 - - - - 80,000
18 AX-300-14-600 1530 30/4P 1440 95,000 - - - - -
19 AX-300-96-720 1830 30/6P 960 1,20,000 - - - - -
20 AX-500-14-720 1830 50/4P 1440 1,50,000 - - - - -

Fan selection based on air at 20°C, density 1.2 kg/m³. Performance and tolerance as per IS 3588-1987. Custom sizes and intermediate performance points available on request.

Product Images

Wall Mounted Industrial Tube Axial Fan
Factory Wall Mounted Axial Fan
Tube Axial Fan Range
Axial Fan Installation

Where It Is Used

FACTORY & UTILITY AREAS

  • Factory Side-Wall Exhaust: Removing heat, fumes, and stale air through external wall.
  • Warehouse Fresh Air Supply: Through-wall supply fans on windward wall.
  • Server & UPS Rooms: Continuous heat exhaust through external wall.
  • Electrical Switch Rooms: Forced cooling air supply for transformer rooms.
  • Kitchen & Canteen Exhaust: Smoke and cooking fumes through external wall.
  • Toilet & Locker Rooms: Standard exhaust ventilation through building wall.

PROCESS & SPECIALIZED AREAS

  • Chemical Storage Buildings: Solvent vapour dilution and purge ventilation.
  • Battery Charging Rooms: Hydrogen dilution exhaust through external wall.
  • Cold Storage Buildings: Defrost air circulation and heat removal.
  • Car Workshops & Service Bays: Exhaust fume extraction through external wall.
  • Pharmaceutical Coating Rooms: Solvent removal exhaust for tablet coating operations.
  • Laboratories: Chemical fume dilution exhaust ventilation.

You May Also Need

Stand Mounted Fresh Air Fan

Stand Mounted Fresh Air Fan

Flexible floor-standing fresh air supply — repositionable without wall penetration.

View Details →
Base Mounted Axial Fan

Base Mounted Axial Fan

Permanent floor installation for high-capacity fresh air supply and exhaust.

View Details →
Flameproof Floor Mounted Fan

Flameproof Floor Mounted Fan

IS 5572 flameproof for Zone 1 & 2 hazardous area exhaust ventilation.

View Details →
Belt Driven Axial Fan

Belt Driven Axial Fan

Belt-drive variant for high-temperature and corrosive wall exhaust applications.

View Details →

FAQs — Wall Mounted Industrial Tube Axial Fan

The wall opening diameter should be 10 to 20 mm larger than the fan casing outer diameter to allow for installation and sealing. For example, a 610 mm (24") tube axial fan casing typically requires a 630 to 640 mm diameter wall opening. Vayuvents provides the exact required opening dimensions with each fan supply.

Yes. Reversible single-phase and three-phase motors are available for tube axial fans requiring both supply and exhaust operation from the same fan position. The motor rotates in reverse to change airflow direction. However, note that reversed airflow efficiency is slightly lower than forward airflow in standard blade profiles. Vayuvents offers symmetrical blade profile impellers for equal supply and exhaust performance on request.

For outdoor-facing installations, Vayuvents recommends: (1) automatic back-draught shutters that close when the fan is stopped — prevents rain ingress and reverse airflow from wind; (2) aluminium or GRP louvred bird guard to prevent bird nesting; and (3) GI or SS weatherhood for installations in areas with heavy rain or monsoon exposure. All external accessories are supplied and fitted at Vayuvents works.

Standard MS casing fans are not suitable for corrosive chemical fumes. For chemical plant storage buildings, acid fume exhaust, and coastal environments, Vayuvents supplies tube axial fans with FRP (fibre-reinforced plastic) or SS304/316 casings and GRP anti-static impellers that resist chemical attack. Please specify the chemical or corrosive medium when requesting a quotation.

Standard Vayuvents tube axial fan casings accommodate wall thicknesses up to 300 mm. For thicker walls (300 mm to 600 mm), an extended casing length is available on request. For walls above 600 mm thickness, a flanged duct connection to the fan is recommended rather than a longer casing.

Yes. Vayuvents supplies GMP-compatible wall mounted tube axial fans in SS304 or SS316L casing for pharmaceutical production buildings, food processing plants, and clean room exhaust applications. These are supplied with smooth internal surfaces, no dead zones, and are designed for wet cleaning with water and disinfectant.

Contact Vayuvents at enquiry@vayuvents.com or call +91 90961 88703. Share the wall thickness, required airflow in m³/hr, wall opening size if already cut, and any special requirements (reversible, chemical-resistant, flameproof). We will provide a selection and commercial proposal within 24 hours.

Call Now